The generator assembly mounts through 2 bolts reaching 43 Nm of torque which equals 438 kgf-cm (32 ft-lbf). The wire harness connection requires installation of the clamp bracket secured by two 8.0 Nm (82 kgf-cm, 71 in-lbf) torque bolts followed by harness attachment at terminal B with a nut tightened to 9.8 Nm (100 kgf-cm, 7 ft-lbf). After connecting the connector to the generator assembly install the wire harness stay by using a bolt which needs 8.0 Nm (82 kgf-cm, 71 in-lbf) of torque. The installation starts with the generator followed by battery and fan and generator V belt installation. The engine No. 1 under cover sub-assembly should be installed while tightening the 4 bolts to 29 Nm (296 kgf-cm, 21 ft-lbf).